New generation FCA-90S-G4 power unit
Compatible with small, medium and long-haul aircrafts
Touchscreen
Electricity metering system
Full diagnostic turn-up test
400% overload within 2 seconds
Designed to comply with RoHS and REACH requirements
Power units of FCA series are designed to supply aircrafts during preflight maintenance at the airport. They can also be used as a power unit of test benches, hangars and aircraft manufacturing plants.
FCA-90S-G4 is intended to supply all types of aircrafts with 400 Hz frequency and 3x115/200 VAC voltage during preflight preparation and technical maintenance.Can be manufactured in both standard complete set and also by Client’s special requirements and adjustments.
• Smart operational TFT display
• Full diagnostic turn-up test
• Energy consumption metering system
• Modularity
• Maximum individual protection
• Innovative design
• Easy operation and maintenance
• A380, B787 compatible
• Outgoing 400 Hz 3 phase sinusoidal voltage high quality
• High efficiency factor
• Energy consumption low level
Output parameters: | |
Rated output power, kVA | 90 |
Rated output voltage phase/line, V | 3 x 115/200 |
Output voltage frequency, Hz | 400 ± 0,001 |
Output voltage regulation accuracy, %: | |
— for the balanced load | ± 0,5 |
— for 30 % unbalanced load | ± 0,5 |
Total harmonic content, % | |
— linear | ≤ 2 |
— non-linear load | ≤ 2 |
Voltage modulation, % | ≤ 1 |
Phase symmetry, electrical degree: | |
— for the balanced load | 120 ± 1 |
— for 30 % unbalanced load | 120 ± 1 |
Power factor | 0,8 – 1,0 |
Range of load change, % | 0 – 100 |
Voltage value change at 100 % load connection, % | ≤ 10 |
Crest factor | 1,414 ± 0,03 |
Permissible overload, %: | |
— during 600 seconds | 150 |
— during 30 seconds | 200 |
— during 10 seconds | 250 |
— during 5 seconds | 300 |
— during 2 second | 400 |
Input parameters: | |
Supply main rated voltage, V | 3 x 400 (380) |
Supply main permitted deviation, % | ± 15 |
Supply main rated frequency, Hz | 50/60 |
Supply main permitted frequency deviation, % | ± 10 |
Power factor at 100% load | ≥0.97 |
The total value of the harmonic distortion factor of the current at the input,% | ≤ 5 |
Power consumption: | |
— in standby mode with the switch off switch, W | ≤ 50 |
— idling, kW | ≤ 1 |
Efficiency in nominal mode,% | ≥ 96 |
Power interruption | till 25 ms |
Starting current | no, soft start |
Additional data: | |
Dimensions (WxHxD), mm | 600 х 1200 х 600 |
Weight, kg | ≤ 365 |
Ingress protection | IP55 |
Max temperature conditions, ºС | + 56 |
Min temperature conditions, ºС | - 40 |
Aqustic noise level (1 m) | 55 dB |
Humidity, % | 0-100 |
Portfolio
FCA-90M
FCA-90/AR-600M
AR-2×600
FCA-90М
FCA90/AR-2х600-М
FCA-90S
FCA-90S
FCA-90S, FCA-15
AR-400, FCA-63
FCA-100
FCA-63/AR-400, FCA-90S, FCA-120S
AR-400, FCA-90S
AR-400, FCA-90S, FCA-30
FCA-10-6S
FCA-90/АВ-1-600х28,5 (mobile)
FCA-90-12M (mobile)
Any questions?
Contact us, we will be happy to answer!
Phone: +372 6228 395